The compressor is the pump that moves refrigerant through the system. Not every unit that blows warm air needs a new one. Diagnosis checks the capacitor, relay, wiring, power supply, and refrigerant charge first. Replacement is advised only when the windings are open or grounded, or the pump is mechanically seized.
825
Directory listings
46
Provinces with providers
₱500
Indicative low
₱18,000
Indicative high
Price table
Indicative Philippine market ranges by unit type. These are not quotes from any listing.
| Unit type | Indicative low | Indicative high | Notes |
|---|---|---|---|
| Compressor diagnosis | ₱500 | ₱1,000 | Electrical and pressure testing before any part is replaced. |
| Start capacitor or relay | ₱800 | ₱2,000 | Often mistaken for a compressor failure. |
| Window type compressor replacement | ₱4,500 | ₱8,000 | Includes labor, vacuum, and recharge. |
| Split type, 1.0 to 1.5 HP | ₱6,000 | ₱12,000 | Compressor and labor, depending on brand. |
| Split type, 2.0 to 3.0 HP | ₱10,000 | ₱18,000 | Larger capacity units cost more to replace. |
| Electrical repair only | ₱1,500 | ₱4,000 | Terminal, wiring, or start circuit repair. |
Ask the technician to write the diagnosis, the parts to be replaced, the refrigerant to be used, and the labor charge as separate lines. A quote that only gives one total is hard to compare and easy to inflate.
For a major part, ask whether it is new, rebuilt, or surplus. Confirm the warranty in writing. If the shop cannot explain why the part failed, get a second opinion before approving the work.
Province links
Provinces with listings that mention this service. Each link opens the full local directory.
Providers
These shops carry the general aircon repair tag. Confirm the specific component job before booking.

Pandi, Bulacan

Parañaque, Metro Manila

Las Piñas, Metro Manila

Davao City, Davao del Sur

Manila, Metro Manila

Davao City, Davao del Sur

Davao City, Davao del Sur

Davao City, Davao del Sur
Related services
Freon Recharge
A sealed aircon system should not lose refrigerant. If cooling drops, the usual cause is a leak, not old age. A proper recharge means finding and fixing the leak, vacuuming the line, then charging by weight. Topping up without a repair buys a few weeks of cooling, no more.
Aircon Condenser Repair
The condenser is the outdoor coil that releases heat from your room. If it is dirty, blocked, or its fan is weak, the unit cools poorly and the compressor runs hot. Repair can mean cleaning, a fan motor or capacitor replacement, or coil repair. It is different from indoor unit cleaning.
Split Type Aircon Repair
Split systems have an indoor and an outdoor side. Indoor faults show as weak airflow, water leaks, or noise. Outdoor faults show as no cooling, tripping, or a hot compressor. Diagnosis checks both sides before parts are replaced. Typical repairs cover the PCB, fan motor, sensors, drain pump, and compressor.